MIL-DTL-62265C(AT)
maintaining flow rate. The bubble point shall not be below the minimum established during
preproduction or initial production testing (see 4.9.7).
TABLE IV. Collapse pressure.
Assembly
Differential pressure (pounds
Rated flow
per square inch) (psi)
(gal/min)
12257235
250
10
12270316-1
150
12
12270316-2
150
3
3.4.8 Flow fatigue. The filter element shall be capable of withstanding flow fatigue
cycling specified in table V without evidence of structural failure. The bubble point shall not be
less than the minimum value established during preproduction or initial production testing
(see 4.9.8).
TABLE V. Flow fatigue.
Pressure drop (pounds per
square inch gage) (psig)
Number cycles 12257235
12270316-1, -2
225 000
20
20
22 500
50
50
2 000
100
75
500
150
100
3.4.9 Relief valve performance.
3.4.9.1 Cracking pressure. The relief valve shall crack at the differential pressure
specified in table VI. Cracking pressure is defined as that pressure at which leakage through the
valve exceeds that specified in table VI (see 4.9.9.1).
TABLE VI. Relief valve.
Flow capacity
Cracking
Reseat
Differential Differential
Leakage cubic
Differential
Rate
pressure
pressure
centimeters per
pressure
Leakage
(cm2/min)
min (cm2/min)
Assembly
(gal/min)
(psi)
(psi)
(psi)
125 ±25
12257235
15.5
190
16
60
8
50 ±5
12270316-1
18
120
4
30
2
50 ±5
12270316-2
4.5
120
4
30
2
6