MS17982D
TABLE II. Capacities for R-22 (Btuh). 1/ 2/ 3/
MS PIN |
135°F condensing temp, 125 °F vapor free liquid entering thermostatic expansion valve (TEV) |
105°F conditioning temperature 85°F vapor free liquid entering TEV |
||||||||||
-10°F evaporator (EVAP) temperature 250 psi pressure drop (PD) |
25°F EVAP temperature 220 psi PD |
-10°F EVAP temperature 220 psi PD |
25°F EVAP temperature 200 psi PD |
50°F EVAP temperature 175 psi PD |
50°F EVAP temperature 75 psi PD |
|||||||
MS17982 |
Min |
Max |
Min |
Max |
Min |
Max |
Min |
Max |
Min |
Max |
Min |
Max |
-13 |
3,250 |
5,020 |
5,330 |
16,380 |
||||||||
-14 |
5,850 |
8,830 |
10,250 |
14,300 |
||||||||
-15 |
7,550 |
14,600 |
14,350 |
25,000 |
||||||||
-16 |
14,250 |
32,200 |
30,000 |
49,800 |
||||||||
-17 |
21,800 |
47,000 |
40,000 |
71,500 |
||||||||
-18 |
22,200 |
30,700 |
18,800 |
24,500 |
||||||||
-19 |
47,700 |
58,000 |
38,800 |
41,500 |
||||||||
-20 |
68,000 |
88,500 |
54,700 |
66,000 |
||||||||
-21 |
97,000 |
128,000 |
68,000 |
102,000 |
||||||||
-22 |
122,500 |
133,000 |
92,500 |
102,000 |
||||||||
-23 |
185,700 |
222,000 |
134,000 |
150,000 |
||||||||
-24 |
242,000 |
293,000 |
188,800 |
221,000 |
1/ Minimum capacity requirements must be met.
2/ Maximum capacities are merely for the application engineer.
3/ The suffix "A" in tables III and IV does not affect capacity.