MS17982D
TABLE I. Capacities for R-12 (British Thermal units per hour (Btuh)). 1/ 2/ 3/
MS PIN 4/ |
135°F condensing temp, 125°F vapor free liquid entering Thermostatic Expansion Valve (TEV) |
105°F conditioning temperature 85°F vapor free liquid entering TEV |
||||||||||
-10°F evaporator (EVAP) temperature 175 psi pressure drop (PD) across TEV |
25°F EVAP. temperature 145 psi PD across TEV |
-10°F EVAP temperature 145 psi PD across TEV |
25°F EVAP temperature 125 psi PD across TEV |
50°F EVAP temperature 100 psi PD across TEV |
50°F EVAP temperature 35 psi PD across TEV |
|||||||
MS17982 |
Min |
Max |
Min |
Max |
Min |
Max |
Min |
Max |
Min |
Max |
Min |
Max |
-1 |
2,000 |
3,700 |
3,400 |
7,000 |
||||||||
-2 |
3,600 |
4,200 |
6,300 |
8,800 |
||||||||
-3 |
4,500 |
8,700 |
6,200 |
15,000 |
||||||||
-4 |
8,500 |
19,200 |
18,000 |
30,000 |
||||||||
-5 |
13,000 |
28,000 |
24,000 |
43,000 |
||||||||
-6 |
13,000 |
18,000 |
10,000 |
13,000 |
||||||||
-7 |
28,000 |
34,000 |
19,000 |
22,000 |
||||||||
-8 |
40,000 |
52,000 |
29,000 |
35,000 |
||||||||
-9 |
57,000 |
75,000 |
36,000 |
54,000 |
||||||||
-10 |
72,000 |
78,000 |
49,000 |
54,000 |
||||||||
-11 |
109,000 |
130,000 |
71,000 |
83,000 |
||||||||
-12 |
145,000 |
172,000 |
100,000 |
117,000 |
1/ Minimum capacity requirements must be met.
2/ Maximum capacities are merely for the application engineer.
3/ The suffix "A" in tables III and IV does not affect capacity.
4/ Part or Identifying Number (PIN).
2
For Parts Inquires call Parts Hangar, Inc (727) 493-0744
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business