MS17982D
TABLE I. Capacities for R-12 (Btuh) -Continued. 1/ 2/ 3/ 4/
MS PIN |
57.2°C condensing temp, 51.7°C vapor free liquid entering Thermostatic Expansion Valve (TEV) |
40.6°C conditioning temperature 29.4°C vapor free liquid entering TEV |
||||||||||
-23.3°C evaporator (EVAP) temp 12.1 bar pressure drop (PD) across TEV |
-3.9°C EVAP. temperature 10.0 bar PD across TEV |
-23.3°C EVAP temperature 10.0 bar PD across TEV |
-3.9°C EVAP temperature 8.6 bar PD across TEV |
10.0°C EVAP temperature 6.9 bar PD across TEV |
10.0°C EVAP temperature 2.4 bar PD across TEV |
|||||||
MS17982 |
Min |
Max |
Min |
Max |
Min |
Max |
Min |
Max |
Min |
Max |
Min |
Max |
-1 |
137.9 |
255.1 |
234.4 |
482.6 |
||||||||
-2 |
248.2 |
289.6 |
434.4 |
606.7 |
||||||||
-3 |
310.3 |
599.8 |
427.5 |
1034.2 |
||||||||
-4 |
586.1 |
1323.8 |
124.1 |
2068.4 |
||||||||
-5 |
896.3 |
1930.5 |
1654.7 |
2964.7 |
||||||||
-6 |
896.3 |
124.1 |
689.5 |
896.3 |
||||||||
-7 |
1930.5 |
2344.2 |
1310.0 |
1516.8 |
||||||||
-8 |
2757.9 |
3585.3 |
1999.5 |
2413.2 |
||||||||
-9 |
3930.0 |
5171.1 |
2482.1 |
3723.2 |
||||||||
-10 |
4964.2 |
5377.9 |
3378.4 |
3723.2 |
||||||||
-11 |
7515.3 |
8963.2 |
4895.3 |
5722.7 |
||||||||
-12 |
9997.4 |
11859.0 |
6894.8 |
8066.9 |
1/ Minimum capacity requirements must be met.
2/ Maximum capacities are merely for the application engineer.
3/ The suffix "A" in tables III and IV does not affect capacity.
4/ Metric equivalents are given for information only.