MIL-PRF-9439F
metal diaphragm kept the lubrication and contaminant on the handwheel shaft from entering the
valve and creating a fire hazard.
6.9 Breakaway of bubbles. The breakaway of bubbles is the formation and breaking
away of bubbles on the surface of a submerged test valve while applying internal pressure. The
formation of bubbles is acceptable but breaking away is not.
6.10 Oxygen bomb test. A previously acceptable design of this pressure delivery system
was a 0.188 inch ID, corrosion-resistant steel tube approximately 6 inches long with a bend of
less than 4 degrees.
6.11 Subject term (key word) listing.
Breathing
Shut-off
2,100 psig system
6.12 Changes from previous issue. Marginal notations are not used in this revision to
identify changes with respect to the previous issue due to the extent of the changes.