INCH-POUND
MIL-PRF-9439F
27April 2009
SUPERSEDING
MIL-PRF-9439E
17 July 1998
PERFORMANCE SPECIFICATION
VALVES, OXYGEN CYLINDER, HIGH PRESSURE
This specification is approved for use by all Departments and Agencies of the
Department of Defense.
1. SCOPE
1.1 Scope. This specification covers manually operated, high pressure, aeronautical,
oxygen cylinder valves.
1.2 Classification. Valves covered by this specification are classified according to the
following sizes, as defined in figure 1:
0.5 inch aeronautical pipe thread (ANPT) inlet
Size 1
1.0 inch ANPT inlet
Size 2
1.3 Part or Identifying Number (PIN). The PIN to be used for valves acquired to this
specification is created as follows:
9439
-X
M
Size (see 1.2)
Specification number
Prefix for military specification
Comments, suggestions, or questions on this document should be addressed to Oklahoma City Air
Logistics Center/ENSDAA, 3001 Staff Drive, Tinker AFB, OK 73145-3036 or emailed to
af71@tinker.af.mil. Since contact information can change, you may want to verify the currency of
this address information using the ASSIST Online database at https://assist.daps.dla.mil.
AMSC N/A
FSC 4820
For Parts Inquires call Parts Hangar, Inc (727) 493-0744