MIL-PRF-25675C
STANDARD
DEPARTMENT OF DEFENSE
MS33514
-
Fitting End, Standard Dimensions for Flareless Tube Connection and Gasket Seal
(Unless otherwise indicated, copies of the above specifications and standards are available from the Standardization
Document Order Desk, 700 Robbins Avenue, Building 4D, Philadelphia, PA 19111-5094.)
2.3
Non-Government publications. The following document forms a part of this document to the extent specified
herein. Unless otherwise specified, the applicable issues of the documents that have been adopted by the DoD are
those listed in the specific issue of the DoDISS cited in the solicitation. Unless otherwise specified, the documents not
listed in the DoDISS are the issues of the documents cited in the solicitation (see 6.2).
SOCIETY OF AUTOMOTIVE ENGINEERS (SAE)
SAE AS 4395
-
Fitting Ends, Flared Tube Connection, Design Standard
(Application for copies should be addressed to Society of Automotive Engineers, Inc., 400 Commonwealth Drive,
Warrendale, PA 15096-0001.)
2.4
Order of precedence. In the event of a conflict between the text of this document and the references cited
herein, except for related associated specifications or specification sheets, the text of this document takes precedence.
Nothing in this document, however, supersedes applicable laws and regulations unless a specific exemption has been
obtained. If there is a conflict between the contents of this specification and an associated specification or
specification sheet, the associated specification or specification sheet will apply.
3.
REQUIREMENTS
3.1
Qualification. The valve furnished under this specification shall be products that are authorized by the
qualifying activity for listing on the applicable qualified products list before contract award (see 4.2. and 6.3).
3.2
Recycled, recovered, or environmentally preferable materials. Recycled, recovered, or environmentally
preferable materials should be used to the maximum extent possible provided that the materials meet or exceed the
operational and maintenance requirements, and promote economically advantageous life cycle cost.
3.3
Materials. All materials shall not produce toxic or deleterious fumes and shall be resistant to corrosion due to
electrolytic decomposition, hydraulic fluids, salt fog, or any other conditions that may be encountered during
operational use or storage.
3.4
Interface.
3.4.1
Dimensions. The weight and dimensions of the valve shall conform to Figure 1 and Figure 2.
3.4.2 Hydraulic fluid compatibility. The valve shall be compatible with hydraulic fluid conforming to MIL-H-5606
and MIL-H-83282 in a hydraulic system (see 6.4).
2
For Parts Inquires call Parts Hangar, Inc (727) 493-0744