MS28052C
Dimension |
Dimension |
Tolerance |
||
Inch |
mm |
Inch |
mm |
|
A |
1.125 |
28.575 |
||
B |
.428 |
10.871 |
±.015 |
±.381 |
C |
.600 max |
15.240 max |
||
D1 |
.688 hex |
17.475 hex |
||
D2 |
.251 dia |
6.375 dia |
±.003 |
±.076 |
D3 |
.078 dia |
1.981 dia |
±.003 |
±.076 |
D4 |
.062 dia |
1.575 dia |
±.003 |
±.076 |
D5 |
.096 max .059 min |
2.438 max 1.499 min |
||
E |
.157 |
3.988 |
+.015 -.000 |
+.381 -.000 |
F |
.550 |
13.970 |
||
G |
.063 max |
1.600 max |
||
H |
.005 |
.127 |
+.005 -.000 |
+.127 -.000 |
R |
.005 max |
.127 max |
NOTES:
1. Dimensions are in inches.
2. Metric equivalents are given for information only.
3. Unless otherwise noted, tolerances are ±.016 inch (±.406 mm) and angles ± 0.5°.
FIGURE 1. Valve, check, dimensions and configuration - Continued. REQUIREMENTS
Valve type dash number (see table I).
TABLE I. Valve type dash numbers.
Dash number |
Item |
Boss |
-1 |
Bleeder check valve |
AND10050-4 |
-2 |
Filler check valve |
Performance requirements. Internal designs, other than what is shown on figure 1, shall be acceptable provided external dimensions and performance requirements are met as follows:
a. Valve to hold, with slight leakage, to 2 psi (13.8 MPa).
b. Valve shall break open between 2 psi and 5 psi (13.8 MPa and 34.5 MPa).
c. Maximum leakage under 2 psi (13.8 MPa) to be 3 cubic inches (50 cubic centimeters) of air per minute.
3
Source: https://assist.dla.mil -- Downloaded:
Check the source to verify that this is the current version before use.
For Parts Inquires call Parts Hangar, Inc (727) 493-0744
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business