MIL-PRF-25961H
4.4.1 Temperature and pressure. Unless otherwise specified, tests shall be conducted at
ambient temperature and pressure.
4.4.2 Female filler valve. A CRU-59/E valve shall be used in testing.
4.4.3 Oxygen. All tests requiring LOX shall use oxygen conforming to SAE AS 8010,
Type II, or nitrogen in accordance with A-A-59503, Type II, Class I, Grade B. Testing requiring
gases shall use oxygen in accordance with SAE AS 8010, Type I, or nitrogen in accordance with
A-A-59503, Type I, Class I, Grade B.
4.5 Requirements cross-reference matrix. Table I provides a cross-reference matrix of the
section 3 requirements tested or verified in the paragraphs below.
TABLE I. Requirements cross-reference matrix
Requirements
Verification
Requirements
Verification
3.1
4.2
3.7.5.2
4.6.5
3.3
4.6.1
3.7.5.3
4.6.6
3.4
4.6.1, 4.6.13,.4.6.19
3.7.6.1
4.6.7
3.4.1
4.6.1, 4.6.20
3.7.6.2
4.6.8
3.5.1
4.6.1
3.7.6.3
4.6.9
3.5.2
4.6.1
3.7.7.1
4.6.15
3.5.3
4.6.1, 4.6.13
3.7.7.2
4.6.13.3
3.5.4
4.6.1
3.7.8
4.6.12
3.6
4.6.10, 4.6.11, 4.6.16
3.7.9
4.6.14
3.7.1
4.6.13
3.7.10
4.6.1
3.7.2
4.6.13
3.7.11
4.6.17
3.7.3
4.6.2
3.7.12
4.6.18
3.7.4
4.6.1, 4.6.3
3.8
4.6.1
3.7.5.1
4.6.4
4.6 Tests.
4.6.1 Examination of product. Each valve shall be inspected to determine conformance to
workmanship, weight, port locations, thread size, dimensions, fill check element, fittings,
materials, cap requirements, and item identification.
4.6.2 Cleanliness. Cleanliness of the surfaces shall be demonstrated by industrially
accepted methods and shall meet the requirements specified (see 3.7.3). These cleaning and
verification methods shall be identified (see 6.2 and 6.6).