MIL-PRF-23256C
3.5.7 Low temperature. The seal valve assembly shall not show any evidence of mechanical
or material failure and shall meet the leakage and operating pressure requirements (see 3.5.3 and
3.5.4), when tested as specified in 4.5.7.
3.5.8 Thermal shock. The seal valve assembly shall not show any evidence of mechanical or
material failure and shall meet the leakage and operating pressure requirements (see 3.5.3 and
3.5.4), when tested as specified in 4.5.8.
3.5.9 Salt fog. The seal valve assembly shall not show any evidence of mechanical or
material failure and shall meet the leakage and operating pressure requirements (see 3.5.3 and
3.5.4), when tested as specified in 4.5.9.
3.5.10 Humidity. The seal valve assembly shall not show any evidence of mechanical or
material failure and shall meet the leakage and operating pressure requirements (see 3.5.3 and
3.5.4), when tested as specified in 4.5.10.
3.5.11 Vibration. The seal valve assembly shall not show any evidence of mechanical or
material failure and shall meet the leakage and operating pressure requirements (see 3.5.3 and
3.5.4), when tested as specified in 4.5.11.
3.5.12 Shock. The seal valve assembly shall not show any evidence of mechanical or
material failure and shall meet the leakage and operating pressure requirements (see 3.5.3 and
3.5.4), when tested as specified in 4.5.12.
3.5.13 Service life. The seal valve assembly shall not show any evidence of mechanical or
material failure and shall meet the leakage and operating pressure requirements (see 3.5.3 and
3.5.4), when tested as specified in 4.5.13.
3.5.14 Burst pressure. The seal valve assembly shall not show any evidence of permanent
deformation when tested as specified in 4.5.14.
3.6 Interchangeability. All parts having the same part number shall be functionally and
dimensionally interchangeable.
3.7 Cleanliness. The seal valve assembly and all internal parts shall be free of water, oils,
grease, and any foreign matter.
3.8 Identification of product. The seal valve assembly shall be marked for identification in
accordance with MIL-STD-130, except the Federal Stock Number shall be omitted to ensure the
seal valve assembly is properly and legibly identified as required.